Notes from Daily Encounters with Technology RSS 2.0
 
# Saturday, August 01, 2009

Today I decided to get to the bottom of the missing driver issue on my computer running Windows 7 RC. It shows up as PCI Simple Communications controller and it really bugged me since I don't have a modem or a similar device on the motherboard.

PCI Simple Communications ControllerIt turned out that there is a away to identify such a device from the information available in Device Manager. The first step is to open the Properties window for this device and move to the Details tab. After selecting the Hardware Ids in the Property dropdown the device identifiers are displayed.

HardwareIds

The important ones are the numbers written after the VEN and DEV keywords. The first one is the Vendor ID and the second one is the Device ID. So in my case the Vendor ID is 8086 (from VEN_8086) and the Device ID is 29A4 (from DEV_29A4).

All that's left to do know is to go to PCIDatabase.com and enter the ids into the corresponding search boxes. In my case it turned out that it was a device from Intel - Intel Management Engine Interface (HECI). Unfortunately it doesn't have a driver for Windows 7 yet and the Vista one doesn't install. But hey, at least I know which driver is missing.

Saturday, August 01, 2009 7:09:49 PM (Central European Daylight Time, UTC+02:00)  #    Comments [2] - Trackback
Software | Windows
# Saturday, July 05, 2008

Gama System eArchive, one of the two products in our document product line, received accreditation from the Archives of the Republic of Slovenia last week. This acknowledgement by our national body means that any document stored in Gama System eArchive is automatically legally valid.

This is important for both our company and other companies looking for a long term electronic document storage solution. Our product is the first service oriented solution to receive the accreditation.

Congratulations to everyone involved in the product. Well done!

Saturday, July 05, 2008 10:37:14 PM (Central European Daylight Time, UTC+02:00)  #    Comments [1] - Trackback
Development | .NET | Personal | Work
# Sunday, June 15, 2008

Today I've taken my new handeld GPS device for a test run. It did its job pretty well but the real challenge started afterwards when I tried geotagging the photos I've taken. I decided to use Microsoft Pro Photo Tools which have just been released with geotagging as its main feature. Downloading the track data from the GPS device with Garmin MapSource software was quick and simple. But the problems started soon afterwards. MapSource can only export track data in its proprietary format GDB which can't be used in Microsoft Pro Photo Tools.

GPSBabel came to the rescue. This free tool can probably convert files between any two existing GPS formats, at least judging from its list of supported formats. I used it to convert my data to the GPX XML format only to find out that Microsoft Pro Photo Tools have problems with it. Converting to NMEA or KML instead didn't help either. Fortunately the latter returned a strange error (Degrees must be between 0 and 90, found degree 46298501) which put me on the right track. Of course there was no such value in the KML file so I correctly deduced that the decimal separator was to blame.

The value in the file was 46.298501 but the Slovenian regional settings have comma as the decimal separator therefore the value was misinterpreted. Temporarily changing the decimal separator to dot solved the problem - the track was successfully imported immediately afterwards. This issue won't keep me from using this otherwise very useful tool with a really nice feature set. It could even fix the mismatching time settings between my GPS unit and the camera with a single setting. I just hope they address this bug soon so that I won't have to change my regional settings every time I use the program.

The only thing I still have to figure out is why the geotags somehow lost resolution when I uploaded the photos from Picasa to Picasa Web Albums. I just fixed them manually and decided to address the issue next time. Any tips are welcome.

Sunday, June 15, 2008 10:03:01 PM (Central European Daylight Time, UTC+02:00)  #    Comments [0] - Trackback
Software | Imaging
# Tuesday, April 29, 2008

A .NET application in the company I work for recently started crashing under Windows Vista when trying to open a window implemented in an ActiveX DLL. Investigations showed that they were caused by an AccessViolationException "Attempted to read or write protected memory. This is often an indication that other memory is corrupt.". The cause was one of the ActiveX controls in the window. When instantited directly in a .NET Form the exception above was contained in a TargetInvocationException "Unable to get the window handle for the '<control name>' control. Windowless ActiveX controls are not supported.". Knowing that the control didn't suddenly turn windowless we dug deeper.

It turned out that the problem appeared with .NET Framework 2.0 Service Pack 1. Apparently it caused the C# compiler in Visual Studio 2005 and later to set the NXCOMPAT bit for all build targets without an option to turn this new behavior off. For those who don't know, this means that DEP (data execution prevention) will kick in unless it is turned off completely in the operating system. This wouldn't be a big deal unless ATL before Visual Studio 2005 didn't have a bug which caused the heap allocated memory not to be flagged as executable, which under the new circumstances results as the already mentioned exception. Windows XP has DEP turned off by default therefore everything still works but in Windows Vista it is turned on and prevents such application from functioning properly.

The best solution would of course be to recompile the ActiveX controls in Visual Studio 2005 or later but this might not be possible if they are supplied by a third party. In this case the most obvious approach to dealing with the situation is to disable DEP in Vista. There is a Data Execution Prevention tab in the Performance Options which open when you click the Settings button in the Performance frame of the Advanced tab in the System Properties dialog but it only allows switching between DEP for all processes with defined exceptions and DEP for essential Windows programs and services, i.e. executables flagged with the NXCOMPAT bit. The only way to turn DEP completely off is executing the following command with administrative privileges:

bcdedit.exe /set {current} nx AlwaysOff

After restart DEP will be turned off and problematic binaries will work once again. To restore the previous (default) state replace AlwaysOff with OptIn. The AlwaysOn option enables DEP for all processes and might cause additional problems (e.g. Google Calendar Sync in its current version 0.9.3.2 doesn't work in this mode).

Unfortunately, this solution would require all your Vista using customers to disable DEP as well which really isn't an option for commercial software. Fortunately, there is another solution. Although there is no compiler option to turn keep the NXCOMPAT bit unset, you can still do this after compilation using the editbin.exe which comes with C++ compiler for Visual Studio 2005 and later:

editbin.exe /NXCOMPAT:NO <filename.exe>

This command removes the NXCOMPAT bit and restores the behavior before .NET 2.0 SP1. If your assembly was signed it also invalidates the signature so you'll have to resign it:

sn.exe -R <filename.exe> <keyfile.snk>

You can automate this by putting the two commands in the Post-build event command line for the project:

editbin.exe /NXCOMPAT:NO "$(TargetPath)"
sn.exe -R "$(TargetPath)" "$(ProjectDir)<keyfile.snk>"

You might need to call vcvars32.bat before that to put the required executables in path and enable editbin.exe dependencies to be resolved. Note that in a completely automated build scenario using MSBuild you'll have to specify full path for the vcvars32.bat because $(DevEnvDir) resolves to *Undefined* outside Visual Studio 2005. Also your strong name key should be in a snk file instead of a password protected pfx file because sn.exe doesn't allow the password to be read from a redirected standard input.

Tuesday, April 29, 2008 3:29:08 PM (Central European Daylight Time, UTC+02:00)  #    Comments [2] - Trackback
Development | .NET | Interop
# Monday, April 14, 2008

The MonthCalendar control's BoldedDates functionality doesn't appear to work properly on Windows Vista. The dates added to any of the BoldedDates, MonthlyBoldedDates and AnnuallyBoldedDates collections are rendered just the same as those not added to any of the collections. The same code works just fine on Windows XP and causes those dates to be rendered bold. The only workaround i've managed to find is disabling visual styles in the application, i.e. commenting out the first line in the Program.Main() method of a new Windows Application:

Application.EnableVisualStyles();

Monday, April 14, 2008 9:54:58 PM (Central European Daylight Time, UTC+02:00)  #    Comments [0] - Trackback
Development | .NET
Sponsored Ads

About Me

Damir Arh

Microsoft Certified Professional

View Damir Arh's profile on LinkedIn

Profile for ExAmigan

ExAmigan

Twitter
Damir's Corner: Avoiding Queue Starvation in CruiseControl.NET http://goo.gl/fb/G52YB 1 day ago
RT @aleksj: From http://last.fm/robots.txt: Disallow: /harming/humans, Disallow: /ignoring/human/orders, Disallow: /harm/to/self #asimov 2 days ago
Eagle Eye on DVD was a pleasant surprise. It passed under my radar when it was first released. 5 days ago
Multiple RTM gadgets in iGoogle suddenly can't show different lists anymore http://digs.by/aD5AbJ 6 days ago
Notifications for new projects in CCTray are a nice new feature of #ccnet 1.5 7 days ago
The opinions expressed herein are my own personal opinions and do not represent my employer's view in any way.

All Content © 2010, Damir Arh, M. Sc. Send mail to the author(s) - Privacy Policy - Sign In
Based on DasBlog theme 'Business' created by Christoph De Baene (delarou)